Everlux UL 924 Listed EXIT Signs



The Everlux EXIT signs are listed for a maximum visibility distance of 50’ as per the requirements of UL 924 Emergency Lighting and Power Equipment.
The luminance performance of the Everlux UL 924 Listed EXIT Signs is compliant the relevant Standards and Building Codes requirements:

According to UL 924
According to UL 924, in stimulation conditions of 54 lux (5 ft-c) during 60 min with a fluorescent cool white source color temperature 4000K, the UL listed Everlux EXIT sign will deliver the following luminance performance:

Time after removing the exciting light (in minutes)Luminance Intensity (mcd/m2
10 minutes
130
60 minutes
30
90 minutes
20

According to R.S 6.1-A
According to RS 6.1, in stimulation conditions of 21.6 lux (2 ft-c) during 120 minutes with a fluorescent cool white source color temperature 4000K, the UL listed Everlux EXIT sign will deliver the following luminance performance:

Time after removing the exciting light (in minutes)Luminance Intensity (mcd/m2
According to RS 6.1

10 minutes
3061.6
60 minutes
721.7
90 minutes
515.5



back